GAME ADJUSTMENT PROCEDURE (Continued)
01 Auto Replay (or Fixed Replay) (Continued)
The game program aids a game's initial installation by performing
a
comparison of the value of the
Replay Level to the player's score every 50 games for the first 800 games. At each comparison,
the program increases (or decreases) the Replay Level by 100,000 to achieve the replay
percent- age specified either via the factory setting or later operator adjustment.
(After the first
800 games, the comparison occurs after every 500 games.) Use the Credit button
to
change
the percentage within the range of 5t050 (%), with the value increasing using AUTO-UP (or
decreasing using MANUAL-DOWN).
The next Credit button change ~
5%
selects the
FIXED REPLAY option.
For AUTO REPLAY, Ad 02 provides the Starting Replay Level (player
i
and 2 displays show RE-
PLAY START). Ad 03 provides the number of replay levels (01,02,03,
or 04).
BIG GUNS
then
proceeds to Ad
06
automatically.
For FIXED REPLAY, Ad 02 is the first replay level (REPLAY LEVEL I). Ad
03,
04, and 05 are
the other replay levels.
02 Starting Replay Level (or Replay Level 1)
For AUTO REPLAY (refer
to
Ad 01), the Factory Setting is
2,500,000
(German games have a
Factory Setting of 2,300,000).
The range of settings is
800,000
through
4,000,000
(by incre-
ments of
100,000
with AUTO-UP or decrements of
100,000
with MANUAL- DOWN).
For FIXED REPLAY, the operator can enter the value to be used for the first fixed replay score
level via the Credit button.
The range of settings is:
OFF; 100,000
through
9.900,000
(by
increments of 100,000 with AUTO-UP, or decrements
of
100,000 with MANUAL-DOWN).
03 Replay Levels (or Replay Level 2)
For AUTO REPLAY (refer to Ad 01), the Factory Setting is 01 (one replay level). The option
range is
one, two. three, or fourreplay
level(s). When the operator chooses
two
replay levels,
BIG GUNS
automatically adjusts the second replay level to be twice the value selected for Ad 02,
the starting replay level. ChOOSing three or four replay levels automatically adjusts their replay
levels to three times or four times the Ad
02
value.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those
of
Ad
02.
04 (Replay Level
3)
For AUTO REPLAY, this Adjustment Item is not applicable.
BfG
GUNS
automatically bypasses
this adjustment.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those
of Ad 02.
05 (Replay Level 4)
For AUTO REPLAY, this Adjustment Item is not applicable.
BIG GUNS
automatically bypasses
this adjustment.
For FIXED REPLAY, the technique of value entry and the range of settings are identical to those
of Ad
02.
06 Replay Award
For either AUTO REPLAY or FIXED REPLAY (Ad 01), the operator can select the form of the
award automatically provided when the player exceeds any Replay Level (Automatic or Fixed).
The choices are:
BIG GUNS
11