GAME ADJUSTMENT PROCEDURE (Continued)
20 Credits for Highest Score 3
This adjustment is similar to Ad 18, except that this applies
'0
'he player's exceeding the third
highest score. The Credit button adjustment technique is the same as for Ad 18. The range of
this setting is
00
through
03.
The Factory Setting is
01.
21 Credits
lor
Highest Score 4
This adjustment is similar to Ad 18, except that this applies to the player's ex.ceeding the fourth
highest score. The Credit button adjustment technique is the same as for Ad 18. The range of
this setting is
00
through
03.
The Factory Selting is 01.
22
Automatic High Score Reset
The operator can specify (via Credit button) that the game will provide an automatic reset of the
displayed "Highest Scores", and the number of games to be played before the reset occurs.
The values provided upon reset are those selected by the operator in Ad 14 through 17, the
Backup High Scores. The range of this setting is
Off(to
disable this adjustment), and
250
to
24,750
games (in increments of 250). The Factory Setting is 3,000. (Audit item 39 displays the
number
of
games remaining before the reset.)
23
Free
Play
The operator can select (via the Credit button) whether a player can opel ate the game without a
coin (free play) or with a coin. The optional alternatives are
No
(a coin is necessary) or
Yes
(game
play is free; no coin is required). The Factory Setting is No.
24
Coinage
Selections
The operator can specify (via the Credit button) any of the 16 Standard Settings for game
pricing, each of which exhibits a message identifying the country and the number of coins
required and the number of games that the coin requirement purchases. Choosing a Standard
Setting permits the game to omit items Ad 25 through 30,which are adjustments allowing
for
a
special custom coinage setting. The Factory Setting is U.S.A. 1 : 1 COIN 1 PLAY, as shown by
the backbox display. (For German games, the Factory Setting is GERMAN2: 7 PLAY 5 dm.)
Following the last Standard Setting is a Custom Coinage Setting, which allows the operator to
utilize Ad 25 through 30 in establishing a special coinage setting.
A message, CUSTOM
COINAGE, indicates that the operator can enter the appropriate values into the Ad 25 through
30 adjustment items.
The values for Ad 25 through 30 of each Standard Setting. as well as other possible values for
the Custom Coinage Setting are shown in the Pricing Table.
25 Left Chute Coin Units
The operator can specify (via the Credit button) the number of coin units purchased by a coin
passing through the left coin chute.
26 Center Chute Coin Units
The operator can specify (via the Credit button) the number of coin units purchased by a coin
passing through the center coin chute.
27 Right Chute Coin Units
The operator can specify (via the Credit button) the number of coin units purchased by a coin
passing through the right coin chute.
BIG GUNS 14