Page 56 - The Machine Bride of Pinbot

Basic HTML Version

DOWNButton -
Not used - except where noted above in the single lamp mode.
.Escape -
Will return you to the Test menu any time it is pressed during the Helmet
Light Test.
When done testing the head cycling, press escape to return to the Test menu. Once in the Test
menu, press the UP button to display the next test (or the DOWNbutton to return to the previous test).
Press enter to activate that test.
'1:.16 Head Manual Control Thst
NOTE: Please read the information concerning the "Head Tests & Head Problems" before using
this test (pg. 32-33).
Once the test name is shown under the test menu, press the enter button. This test is not subject to
the normal homing and calibrating of the other head tests (T.12~T.13, T.14). It will allow you to
manually control the turning on and off of the head motor. The display will show the state of head
position switch (#67) (sw=) and the status of the motor (MR=ONor MR= OFF). This test allows
easier adjustment of the head position switch (#67)by allowing you to start and stop the rotating of
the head while watching in the displays if the head position switch is triggering properly (switch
should be open when on an identation and closedwhen not on an indentation).
Enter Button - Not used in this test.
UPButton-
This will turn the head motor on (rotating clockwise) if the motor was
previously off. If the motor was previously on, it will turn the head motor off
immediately.
DOWNButton -
This will turn the head motor on (rotating counter clockwise) if the motor
was previously off. If the motor was previously on, it will turn the head
motor off immediately.
Escape -
Will return you to the Test menu any time it is pressed during the Head
Manual Test.
When done testing the Helmet Lights, press escape to return to the Test menu. Once in the Test
menu, press the UP button to display the next test (or the DOWNbutton to return to the previous test).
Press enter to activate that test.
Press the Enter button to activate the Utilities Menu, once the menu name is shown under the Main
Menu. Then, use the Up or Down button to cycle through the Utility Menu selections. Press the
Enter button to activate the desired Utility or Utility Group when it appears in the displays. If you
change a utility setting and realize you have made a mistake, press the Escape button while
"Saving Adjustment Value" is still in the displays. The original setting is retained and the new
setting is ignored.
u.
UTILITIES MENU
U.l Clear Audits
U.2 Clear Coins
U.3 Reset
as,
T.D.
THE
MACHINE 1-00