Press the Enter button to activate the Adjustments Menu. Press the Up or Down button to cycle
through the Adjustment Menu selections.
Press the Enter button to activate the desired
Adjustment group when it appears on the display.
A. ADJUSTMENTS MENU
A.I
Standard Adjustments
A.2
Feature Adjustments
A.3
Pricing Adjustments
AA
H.S.T.D Adjustments
A.S
Printer Adjustments (optional board required)
Once you have entered the adjustment group desired, press the Up or Down button to cycle through
the available adjustments in that group. When the desired adjustment appears press the Enter
button to activate that adjustment. When an adjustment is activated, the setting value begins to
flash. Use the Up or Down button to raise or lower the setting value. When the desired value is
displayed press Enter to lock in the value. If you realize you have made an error, press the Escape
button while "Saving Adjustment Value" is displayed. The new value is ignored and the original
value is retained.
A.I
Standard Adjustments
A.I
01 Balls Per Game
The operator defines a "game" by specifying the number of balls to be played. The range
of this setting is
1
through
10.
A.I
02 Tilt Warnings
The operator specifies the number of total actuations of the plumb bob mechanism that
can occur before the game is "tilted". The range of this setting is
1
through 10.
A.l
03 Maximum Extra Balls
The operator chooses the number of Extra Balls that a player may accumulate. The range
of this setting is
1
through
10,
or "No Extra Ball" (Extra Ball disabled).
A.I
04
Maximum Extra Balls/Ball in Play
The operator chooses the number of Extra Balls to be awarded per ball in play. The range
of this setting is:
OFF -
1-10
No maximum number
of
Extra Balls per ball in play.
1 through 10 Extra Balls per ball in play.
The ADDAMS FAMILY 1-28